Prestressing in Coventry Cathedral

Accepted version
Peer-reviewed

Type

Article

Change log

Authors

Burgoyne, Christopher  ORCID logo  https://orcid.org/0000-0002-8092-3344
Mitchell, O 

Abstract

Coventry Cathedral was completed in the early 1960s and has some prestressed elements to resist lateral thrust from the roof. Other prestressed structures of a similar age have had corrosion problems and this has drawn attention to the fact that there is little publicly available information about the structural system at Coventry. This paper addresses that issue and is in three sections. The first summarises the four different prestressing systems in the cathedral and estimates the amount of prestress and its purpose in each location. By placing the information in the public domain it will be useful for both historians of church architecture and engineers in future generations who may have to work on the building. Although there is no evidence of corrosion in the building at the moment, it is impossible to inspect the existing tendons, so the second section considers what might happen to the structure if corrosion of the tendons were to occur. It is concluded that very little warning of failure would be given, which would be especially important for the tendons over the Baptistry window and those in the Nave ties. The final section considers what could be monitored to give as much warning as possible about future problems. The effects of loss of an individual tendon, which would not by itself be sufficient to cause failure of the structure, would cause only very small strains that would be difficult to distinguish from the background strains caused by temperature change. Many of the principles discussed in the second and third sections would be applicable to many other prestressed concrete structures.

Description

Keywords

prestressed concrete, corrosion

Journal Title

Structures

Conference Name

Journal ISSN

2352-0124
2352-0124

Volume Title

11

Publisher

Elsevier