Repository logo
 

A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1-13 C]pyruvate and [1-13 C]lactate.

Published version
Peer-reviewed

Type

Article

Change log

Authors

Hesketh, Richard L 
Hu, De-En 

Abstract

Single-shot echo planar imaging (EPI), which allows an image to be acquired using a single excitation pulse, is used widely for imaging the metabolism of hyperpolarized 13 C-labelled metabolites in vivo as the technique is rapid and minimizes the depletion of the hyperpolarized signal. However, EPI suffers from Nyquist ghosting, which normally is corrected for by acquiring a reference scan. In a dynamic acquisition of a series of images, this results in the sacrifice of a time point if the reference scan involves a full readout train with no phase encoding. This time penalty is negligible if an integrated navigator echo is used, but at the cost of a lower signal-to-noise ratio (SNR) as a result of prolonged T2 * decay. We describe here a workflow for hyperpolarized 13 C EPI that requires no reference scan. This involves the selection of a ghost-containing background from a 13 C image of a single metabolite at a single time point, the identification of phase correction coefficients that minimize signal in the selected area, and the application of these coefficients to images acquired at all time points and from all metabolites. The workflow was compared in phantom experiments with phase correction using a 13 C reference scan, and yielded similar results in situations with a regular field of view (FOV), a restricted FOV and where there were multiple signal sources. When compared with alternative phase correction methods, the workflow showed an SNR benefit relative to integrated 13 C reference echoes (>15%) or better ghost removal relative to a 1 H reference scan. The residual ghosting in a slightly de-shimmed B0 field was 1.6% using the proposed workflow and 3.8% using a 1 H reference scan. The workflow was implemented with a series of dynamically acquired hyperpolarized [1-13 C]pyruvate and [1-13 C]lactate images in vivo, resulting in images with no observable ghosting and which were quantitatively similar to images corrected using a 13 C reference scan.

Description

Keywords

EPI, [1-13C]lactate, [1-13C]pyruvate, ghosting, hyperpolarized, imaging, metabolism, tumours, Animals, Carbon Isotopes, Echo-Planar Imaging, Female, Image Processing, Computer-Assisted, Lactic Acid, Mice, Inbred C57BL, Phantoms, Imaging, Pyruvic Acid, Reference Standards, Signal Processing, Computer-Assisted, Signal-To-Noise Ratio

Journal Title

NMR Biomed

Conference Name

Journal ISSN

0952-3480
1099-1492

Volume Title

31

Publisher

Wiley
Sponsorship
Cancer Research UK (unknown)
Cancer Research UK (CB4100)
Cancer Research UK (C14303/A17197)
Aarhus University (Source: Data Science Research Centre (DSRC)) (15952)
Cancer Research Uk (None)