Repository logo
 

Does reader performance with digital breast tomosynthesis (DBT) vary with experience of 2D mammography?

Accepted version
Peer-reviewed

Type

Article

Change log

Authors

Tucker, L 
Gilbert, FJ 
Astley, SM 
Dibden, A 
Seth, A 

Abstract

Purpose To assess whether individual reader performance with digital breast tomosynthesis (DBT) and two-dimensional (2D) mammography varies with number of years of experience or volume of 2D mammograms read.

Materials and Methods After written informed consent was obtained, 8869 women (age range, 29–85 years; mean age, 56 years) were recruited into the TOMMY trial (A Comparison of Tomosynthesis with Digital Mammography in the UK National Health Service Breast Screening Program), an ethically approved, multicenter, multireader, retrospective reading study, between July 2011 and March 2013. Each case was read prospectively for clinical assessment and to establish ground truth. A retrospective reading data set of 7060 cases was created and randomly allocated for independent blinded review of (a) 2D mammograms, (b) DBT images and 2D mammograms, and (c) synthetic 2D mammograms and DBT images, without access to previous examinations. Readers (19 radiologists, three advanced practitioner radiographers, and two breast clinicians) who had 3–25 (median, 10) years of experience in the U.K. National Health Service Breast Screening Program and read 5000–13 000 (median, 8000) cases per annum were included in this study. Specificity was analyzed according to reader type and years and volume of experience, and then both specificity and sensitivity were analyzed by matched inference. The median duration of experience (10 years) was used as the cutoff point for comparison of reader performance.

Results Specificity improved with the addition of DBT for all readers. This was significant for all staff groups (56% vs 68% and 49% vs 67% [P < .0001] for radiologists and advanced practitioner radiographers, respectively; 46% vs 55% [P = .02] for breast clinicians). Sensitivity was improved for 19 of 24 (79%) readers and was significantly higher for those with less than 10 years of experience (91% vs 86%; P = .03) and those with total mammographic experience of fewer than 80 000 cases (88% vs 86%; P = .03).

Conclusion The addition of DBT to conventional 2D screening mammography improved specificity for all readers, but the gain in sensitivity was greater for readers with less than 10 years of experience.

Description

Keywords

Journal Title

Radiology

Conference Name

Journal ISSN

Volume Title

283

Publisher

Radiological Society of North America
Sponsorship
This work was funded by the National Institute for Health Research’s Health Technology Assessment Programme.