Repository logo
 

Retrofitting of reinforced concrete beams with CFRP straps to enhance shear capacity


No Thumbnail Available

Type

Thesis

Change log

Authors

Hoult, Neil Anthony 

Abstract

A technique has been developed that employs thin Carbon Fibre Reinforced Polymer (CFRP) straps for shear enhancement ofreinforced concrete beams. Previous studies using these straps have employed steel pads on top of the beam to support the strap but this is problematic from a practical point of view. The initial goal of this research was to develop a method of installing the straps without requiring access to the top smface of the slab that still provided effective shear enhancement, thus reducing the costs associated with repair. This novel strap installation method was developed through a series of tensile tests on the straps. It was found that the straps must be kept away from the sharp edges of the concrete, that the strap cross section must be kept flat, and that the material supporting the strap must be sufficiently stiff. Seven T-beam tests were performed to develop a strap configuration that maximized the shear enhancement but could also be installed from under the slab. The chosen installation technique involved drilling holes in the flange and then filling the holes with grout except for a small groove to support the strap. To ensure maximum enhancement, the-straps need to fully penetrate the compression flange of the beam and the amount of flange area removed for the straps should be minimized. The shear capacity is also affected by the size of the loading pad. A Finite Element Analysis determined that holes in the flange act as crack propagators, strap penetration affects the stiffness of the beam and undersized load pads allow shear cracks to form on lower energy paths. Design equations were developed by comparing the predictions of existing shear models using the straps. The most accurate model, a shear friction approach, was then used to develop a retrofit design procedure for use with the straps. To evaluate the long-term performance of the straps and the under-slab installation technique two further T-beam tests were unde1iaken: a sustained load test where the beam was loaded to 80% of its retrofitted capacity for 260 days and a cyclic test where the load was varied between 50 and 80% of the retrofitted capacity for 2.1 million cycles. In both cases the straps withstood the loading. However, the strains in the straps increased over time, an impmiant observation considering the brittle CFRP straps, which led to the development of a model to predict the long-term strap strains.

Description

This thesis is not available on this repository until the author agrees to make it public. If you are the author of this thesis and would like to make your work openly available, please contact us: thesis@repository.cam.ac.uk.


Cambridge University Library can make a copy of this work available only for the purposes of private study and non-commercial research. Copies should not be shared or saved in any shared facilities. Copyright over the content of these works is with their authors. Theses from the Library collection are considered unpublished works and according to UK legislation quoting from them is not allowed without permission from their author.

If you can commit to these terms, please complete the request form which you can find through this link: https://imagingservices.lib.cam.ac.uk/


Please note that print copies of theses may be available for consultation in the Cambridge University Library's Manuscript reading room. Admission details are at http://www.lib.cam.ac.uk/collections/departments/manuscripts-university-archives

Date

Advisors

Keywords

Qualification

Doctor of Philosophy (PhD)

Awarding Institution

University of Cambridge