Repository logo
 

Evaluation of an aortic valve prosthesis: Fluid-structure interaction or structural simulation?

Accepted version
Peer-reviewed

Change log

Authors

Luraghi, G 
Wu, W 
De Gaetano, F 
Rodriguez Matas, JF 
Moggridge, GD 

Abstract

Bio-inspired polymeric heart valves (PHVs) are excellent candidates to mimic the structural and the fluid dynamic features of the native valve. PHVs can be implanted as prosthetic alternative to currently clinically used mechanical and biological valves or as potential candidate for a minimally invasive treatment, like the transcatheter aortic valve implantation. Nevertheless, PHVs are not currently used for clinical applications due to their lack of reliability. In order to investigate the main features of this new class of prostheses, pulsatile tests in an in-house pulse duplicator were carried out and reproduced in silico with both structural Finite-Element (FE) and Fluid-Structure interaction (FSI) analyses. Valve kinematics and geometric orifice area (GOA) were evaluated to compare the in vitro and the in silico tests. Numerical results showed better similarity with experiments for the FSI than for the FE simulations. The maximum difference between experimental and FSI GOA at maximum opening time was only 5%, as compared to the 46.5% between experimental and structural FE GOA. The stress distribution on the valve leaflets clearly reflected the difference in valve kinematics. Higher stress values were found in the FSI simulations with respect to those obtained in the FE simulation. This study demonstrates that FSI simulations are more appropriate than FE simulations to describe the actual behaviour of PHVs as they can replicate the valve-fluid interaction while providing realistic fluid dynamic results.

Description

Keywords

Cardiovascular mechanics, Finite element analysis, Fluid-structure interaction, Polymeric heart valve

Journal Title

Journal of Biomechanics

Conference Name

Journal ISSN

0021-9290
1873-2380

Volume Title

58

Publisher

Elsevier
Sponsorship
British Heart Foundation (SP/15/5/31548)
MRC (MC_PC_14116 v2)
British Heart Foundation (None)