Repository logo
 

A comparison of semi-automated volumetric vs linear measurement of small vestibular schwannomas.

Accepted version
Peer-reviewed

Change log

Authors

Das, Tilak 
Graves, Martin 
Patterson, Andrew 
Donnelly, Neil 

Abstract

OBJECTIVE: Accurate and precise measurement of vestibular schwannoma (VS) size is key to clinical management decisions. Linear measurements are used in routine clinical practice but are prone to measurement error. This study aims to compare a semi-automated volume segmentation tool against standard linear method for measuring small VS. This study also examines whether oblique tumour orientation can contribute to linear measurement error. STUDY DESIGN: Experimental comparison of observer agreement using two measurement techniques. SETTING: Tertiary skull base unit. PARTICIPANTS: Twenty-four patients with unilateral sporadic small (< 15 mm maximum intracranial dimension) VS imaged with 1 mm-thickness T1-weighted Gadolinium enhanced MRI. MAIN OUTCOME MEASURES: (1) Intra and inter-observer intraclass correlation coefficients (ICC), repeatability coefficients (RC), and relative smallest detectable difference (%SDD). (2) Mean change in maximum linear dimension following reformatting to correct for oblique orientation of VS. RESULTS: Intra-observer ICC was higher for semi-automated volumetric when compared with linear measurements, 0.998 (95% CI 0.994-0.999) vs 0.936 (95% CI 0.856-0.972), p < 0.0001. Inter-observer ICC was also higher for volumetric vs linear measurements, 0.989 (95% CI 0.975-0.995) vs 0.946 (95% CI 0.880-0.976), p = 0.0045. The intra-observer %SDD was similar for volumetric and linear measurements, 9.9% vs 11.8%. However, the inter-observer %SDD was greater for volumetric than linear measurements, 20.1% vs 10.6%. Following oblique reformatting to correct tumour angulation, the mean increase in size was 1.14 mm (p = 0.04). CONCLUSION: Semi-automated volumetric measurements are more repeatable than linear measurements when measuring small VS and should be considered for use in clinical practice. Oblique orientation of VS may contribute to linear measurement error.

Description

Keywords

Acoustic neuroma, Measurement, Semi-automated, Vestibular schwannoma, Volumetric, Contrast Media, Cranial Nerve Neoplasms, Gadolinium, Humans, Magnetic Resonance Imaging, Neuroma, Acoustic, Observer Variation, Reproducibility of Results, Tumor Burden, Vestibulocochlear Nerve Diseases

Journal Title

Eur Arch Otorhinolaryngol

Conference Name

Journal ISSN

0937-4477
1434-4726

Volume Title

275

Publisher

Springer Science and Business Media LLC