Validation of a low field Rheo-NMR instrument and application to shear-induced migration of suspended non-colloidal particles in Couette flow.
View / Open Files
Authors
Colbourne, AA
Blythe, TW
Barua, R
Lovett, S
Mitchell, J
Sederman, AJ
Gladden, LF
Publication Date
2018-01Journal Title
J Magn Reson
ISSN
1090-7807
Publisher
Elsevier BV
Volume
286
Pages
30-35
Language
eng
Type
Article
Physical Medium
Print-Electronic
Metadata
Show full item recordCitation
Colbourne, A., Blythe, T., Barua, R., Lovett, S., Mitchell, J., Sederman, A., & Gladden, L. (2018). Validation of a low field Rheo-NMR instrument and application to shear-induced migration of suspended non-colloidal particles in Couette flow.. J Magn Reson, 286 30-35. https://doi.org/10.1016/j.jmr.2017.11.010
Abstract
Nuclear magnetic resonance rheology (Rheo-NMR) is a valuable tool for studying the transport of suspended non-colloidal particles, important in many commercial processes. The Rheo-NMR imaging technique directly and quantitatively measures fluid displacement as a function of radial position. However, the high field magnets typically used in these experiments are unsuitable for the industrial environment and significantly hinder the measurement of shear stress. We introduce a low field Rheo-NMR instrument (1H resonance frequency of 10.7MHz), which is portable and suitable as a process monitoring tool. This system is applied to the measurement of steady-state velocity profiles of a Newtonian carrier fluid suspending neutrally-buoyant non-colloidal particles at a range of concentrations. The large particle size (diameter >200μm) in the system studied requires a wide-gap Couette geometry and the local rheology was expected to be controlled by shear-induced particle migration. The low-field results are validated against high field Rheo-NMR measurements of consistent samples at matched shear rates. Additionally, it is demonstrated that existing models for particle migration fail to adequately describe the solid volume fractions measured in these systems, highlighting the need for improvement. The low field implementation of Rheo-NMR is complementary to shear stress rheology, such that the two techniques could be combined in a single instrument.
Keywords
Couette flow, Low field, Non-colloidal particles, Particle migration, Process monitoring, Rheo-NMR
Identifiers
External DOI: https://doi.org/10.1016/j.jmr.2017.11.010
This record's URL: https://www.repository.cam.ac.uk/handle/1810/279836
Rights
Licence:
http://www.rioxx.net/licenses/all-rights-reserved
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk