Effect of internal moisture content on the TG values of CFRP rods
View / Open Files
Authors
Toumpanaki, E
Lees, JM
Barbezat, M
Terrasi, GP
Publication Date
2018-01-01Journal Title
9th International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering, CICE 2018
Conference Name
9th International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering (CICE 2018), PARIS 17-19 JULY 2018
ISBN
9780000000002
Volume
2018-July
Pages
112-118
Type
Conference Object
Metadata
Show full item recordCitation
Toumpanaki, E., Lees, J., Barbezat, M., & Terrasi, G. (2018). Effect of internal moisture content on the TG values of CFRP rods. 9th International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering, CICE 2018, 2018-July 112-118. https://doi.org/10.17863/CAM.27288
Abstract
DMA tests are used for the material charaterisation of CFRP tendons for civil engineering applications and to assess the high temperature behavior of CFRP prestressed structures by measuring the glass transition temperature Tg. The glass transition temperature is sensitive to the moisture content of the CFRP tendons and standard test methods (e.g. ASTM D7028 (ASTM 2007)) have not yet qualitatively addressed the effect of small moisture content variations from environmental conditions in the Tg values. The effect of the internal moisture content on the Tg values of two CFRP rods with different diameters and manufacturing process is evaluated. Lab conditioned specimens with varying drying time (9, 15, 36 and 210 days) and thus moisture content are tested to
study the effect of small lab conditions variations in the glass transition temperature and the sensitivity of the DMA testing. Exposed specimens at 60°C for roughly 3 years are also investigated to record effect of greater moisture absorption on the Tg values. Two heating runs were conducted for every test to differentiate postcuring effects and mass weight measurements were recorded before and after each heating run. A linear relationship between the mass loss of the specimens due to drying at vacuum and during the heating runs with the glass transition temperature Tg was observed. Post-curing effects could not be clarified even for the dry specimens. The exposed specimens showed a reduction in Tg of 38°C that was reversible after drying. It is recommended that the use of Tg values to infer the degree of curing should be carried out on dry specimens.
Sponsorship
SACAC Ltd, Onassis Foundation
Funder references
Engineering and Physical Sciences Research Council (EP/J002887/1)
Swiss Federal Laboratories for Materials Testing and Research for Industry, Construction and Commerce (Empa) (unknown)
Identifiers
External DOI: https://doi.org/10.17863/CAM.27288
This record's URL: https://www.repository.cam.ac.uk/handle/1810/279920
Rights
Licence:
http://www.rioxx.net/licenses/all-rights-reserved
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk