Leucocyte telomere length and risk of cardiovascular disease: systematic review and meta-analysis.
View / Open Files
Authors
Haycock, Philip C
Heydon, Emma E
Butterworth, Adam S
Thompson, Alex
Willeit, Peter
Publication Date
2014-07-08Journal Title
BMJ
ISSN
1756-1833
Publisher
BMJ
Volume
349
Pages
g4227
Language
eng
Type
Article
Physical Medium
Electronic
Metadata
Show full item recordCitation
Haycock, P. C., Heydon, E. E., Kaptoge, S., Butterworth, A. S., Thompson, A., & Willeit, P. (2014). Leucocyte telomere length and risk of cardiovascular disease: systematic review and meta-analysis.. BMJ, 349 g4227. https://doi.org/10.1136/bmj.g4227
Abstract
OBJECTIVE: To assess the association between leucocyte telomere length and risk of cardiovascular disease. DESIGN: Systematic review and meta-analysis. DATA SOURCES: Studies published up to March 2014 identified through searches of Medline, Web of Science, and Embase. ELIGIBILITY CRITERIA: Prospective and retrospective studies that reported on associations between leucocyte telomere length and coronary heart disease (defined as non-fatal myocardial infarction, coronary heart disease death, or coronary revascularisation) or cerebrovascular disease (defined as non-fatal stroke or death from cerebrovascular disease) and were broadly representative of general populations--that is, they did not select cohort or control participants on the basis of pre-existing cardiovascular disease or diabetes. RESULTS: Twenty four studies involving 43,725 participants and 8400 patients with cardiovascular disease (5566 with coronary heart disease and 2834 with cerebrovascular disease) were found to be eligible. In a comparison of the shortest versus longest third of leucocyte telomere length, the pooled relative risk for coronary heart disease was 1.54 (95% confidence interval 1.30 to 1.83) in all studies, 1.40 (1.15 to 1.70) in prospective studies, and 1.80 (1.32 to 2.44) in retrospective studies. Heterogeneity between studies was moderate (I(2) = 64%, 41% to 77%, Phet<0.001) and was not significantly explained by mean age of participants (P = 0.23), the proportion of male participants (P = 0.45), or distinction between retrospective versus prospective studies (P = 0.32). Findings for coronary heart disease were similar in meta-analyses restricted to studies that adjusted for conventional vascular risk factors (relative risk 1.42, 95% confidence interval 1.17 to 1.73); studies with ≥ 200 cases (1.44, 1.20 to 1.74); studies with a high quality score (1.53, 1.22 to 1.92); and in analyses that corrected for publication bias (1.34, 1.12 to 1.60). The pooled relative risk for cerebrovascular disease was 1.42 (1.11 to 1.81), with no significant heterogeneity between studies (I(2) = 41%, 0% to 72%, Phet = 0.08). Shorter telomeres were not significantly associated with cerebrovascular disease risk in prospective studies (1.14, 0.85 to 1.54) or in studies with a high quality score (1.21, 0.83 to 1.76). CONCLUSION: Available observational data show an inverse association between leucocyte telomere length and risk of coronary heart disease independent of conventional vascular risk factors. The association with cerebrovascular disease is less certain.
Keywords
Cardiovascular Diseases, Humans, Leukocytes, Models, Statistical, Odds Ratio, Regression Analysis, Risk Factors, Telomere Shortening
Sponsorship
Medical Research Council (MR/L003120/1)
British Heart Foundation (None)
British Heart Foundation (None)
Medical Research Council (G0800270)
Identifiers
External DOI: https://doi.org/10.1136/bmj.g4227
This record's URL: https://www.repository.cam.ac.uk/handle/1810/284592
Rights
Attribution-NonCommercial 4.0 International
Licence URL: https://creativecommons.org/licenses/by-nc/4.0/
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk