A new quantitative 3D approach to imaging of structural joint disease.
View / Open Files
Publication Date
2018-06-18Journal Title
Sci Rep
ISSN
2045-2322
Publisher
Springer Science and Business Media LLC
Volume
8
Issue
1
Pages
9280
Language
eng
Type
Article
Physical Medium
Electronic
Metadata
Show full item recordCitation
Turmezei, T., Treece, G., Gee, A., Houlden, R., & Poole, K. (2018). A new quantitative 3D approach to imaging of structural joint disease.. Sci Rep, 8 (1), 9280. https://doi.org/10.1038/s41598-018-27486-y
Abstract
Imaging of joints with 2D radiography has not been able to detect therapeutic success in research trials while 3D imaging, used regularly in the clinic, has not been approved for this purpose. We present a new 3D approach to this challenge called joint space mapping (JSM) that measures joint space width in 3D from standard clinical computed tomography (CT) data, demonstrating its analysis steps, technical validation, and reproducibility. Using high resolution peripheral quantitative CT as gold standard, we show a marginal over-estimation in accuracy of +0.13 mm and precision of ±0.32 mm. Inter-operator reproducibility bias was near-zero at -0.03 mm with limits of agreement ±0.29 mm and a root mean square coefficient of variation 7.5%. In a technical advance, we present results from across the hip joint in 3D with optimum validation and reproducibility metrics shown at inner joint regions. We also show JSM versatility using different imaging data sets and discuss potential applications. This 3D mapping approach provides information with greater sensitivity than reported for current radiographic methods that could result in improved patient stratification and treatment monitoring.
Keywords
Acetabulum, Aged, 80 and over, Humans, Imaging, Three-Dimensional, Joint Diseases, Joints, Reproducibility of Results, Software, Tomography, X-Ray Computed
Sponsorship
Evelyn Trust (unknown)
Evelyn Trust (16011)
Addenbrooke's Charitable Trust (ACT) (OSTEO FUND 9313)
Cambridge University Hospitals NHS Foundation Trust (CUH) (146281)
Wellcome Trust (100676/Z/12/Z)
Identifiers
External DOI: https://doi.org/10.1038/s41598-018-27486-y
This record's URL: https://www.repository.cam.ac.uk/handle/1810/284674
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk