Evaluation of Possible Effects of a Potassium Channel Modulator on Temporal Processing by Cochlear Implant Listeners.
View / Open Files
Authors
Deeks, John M
Guérit, François
Lamping, Wiebke
Billig, Alexander J
Large, Charles H
Saeed, Shakeel R
Harris, Peter
Publication Date
2018-12Journal Title
J Assoc Res Otolaryngol
ISSN
1525-3961
Publisher
Springer Science and Business Media LLC
Volume
19
Issue
6
Pages
669-680
Language
eng
Type
Article
Physical Medium
Print-Electronic
Metadata
Show full item recordCitation
Carlyon, R. P., Deeks, J. M., Guérit, F., Lamping, W., Billig, A. J., Large, C. H., Saeed, S. R., & et al. (2018). Evaluation of Possible Effects of a Potassium Channel Modulator on Temporal Processing by Cochlear Implant Listeners.. J Assoc Res Otolaryngol, 19 (6), 669-680. https://doi.org/10.1007/s10162-018-00694-z
Abstract
Temporal processing by cochlear implant listeners is degraded and is affected by auditory deprivation. The fast-acting Kv3.1 potassium channel is important for sustained temporally accurate firing and is also susceptible to deprivation, the effects of which can be partially restored in animals by the molecule AUT00063. We report the results of a randomised placebo-controlled double-blind study on psychophysical tests of the effects of AUT00063 on temporal processing by CI listeners. The study measured the upper limit of temporal pitch, gap detection, and discrimination of low rates (centred on 120 pps) for monopolar pulse trains presented to an apical electrode. The upper limit was measured using the optimally efficient midpoint comparison (MPC) pitch-ranking procedure; thresholds were obtained for the other two measures using an adaptive procedure. Twelve CI users (MedEl and Cochlear) were tested before and after two periods of AUT00063 or placebo in a within-subject crossover study. No significant differences occurred between post-drug and post-placebo conditions. This absence of effect occurred despite high test-retest reliability for all three measures, obtained by comparing performance on the two baseline visits, and despite the demonstrated sensitivity of the measures to modest changes in temporal processing obtained in other studies from our laboratory. Hence, we have no evidence that AUT00063 improves temporal processing for the doses and patient population employed.
Keywords
AUT00063, cochlear implant (CI), gap detection threshold (GDT), kv3.1, midpoint comparison procedure (MPC), rate discrimination ratio (RDR), temporal processing, Aged, Aged, 80 and over, Auditory Perception, Cochlear Implants, Cross-Over Studies, Deafness, Double-Blind Method, Hearing Tests, Humans, Imidazoles, Middle Aged, Pyrimidines, Shaw Potassium Channels
Sponsorship
Autifony therapeutics
Funder references
Medical Research Council (MC_UU_00005/3)
Identifiers
External DOI: https://doi.org/10.1007/s10162-018-00694-z
This record's URL: https://www.repository.cam.ac.uk/handle/1810/285434
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk