Experimental investigation of NCF-on-tool contact
dc.contributor.author | Avgoulas, EI | en |
dc.contributor.author | Sutcliffe, Michael | en |
dc.date.accessioned | 2018-11-22T00:30:42Z | |
dc.date.available | 2018-11-22T00:30:42Z | |
dc.date.issued | 2017-01-01 | en |
dc.identifier.uri | https://www.repository.cam.ac.uk/handle/1810/285592 | |
dc.description.abstract | The true fibre contact length for NCF-on-tool contact was measured for an area of 8.29 mm × 11.54 mm over a range of normal pressures using microscopy. Contact length was approximately 67% lower than for unidirectional tow-on-tool contact at the same nominal pressure (240 kPa). This is because NCF stitching and gaps between tows significantly reduce fibre contact length compared to tow-on-tool fibre contact measurements. A Hertzian approach was used to estimate contact area from contact length. | en |
dc.title | Experimental investigation of NCF-on-tool contact | en |
dc.type | Conference Object | |
prism.publicationDate | 2017 | en |
dc.identifier.doi | 10.17863/CAM.32946 | |
rioxxterms.licenseref.uri | http://www.rioxx.net/licenses/all-rights-reserved | en |
rioxxterms.licenseref.startdate | 2017-01-01 | en |
dc.contributor.orcid | Sutcliffe, Michael [0000-0001-9729-4460] | |
rioxxterms.type | Other | en |
pubs.funder-project-id | EPSRC (EP/K032798/1) | |
rioxxterms.freetoread.startdate | 2018-01-01 |