Targeting glucose control in preterm infants: pilot studies of continuous glucose monitoring.
View / Open Files
Publication Date
2019-07Journal Title
Archives of Disease in Childhood: Fetal and Neonatal Edition
ISSN
1468-2052
Publisher
BMJ Publishing Group
Language
eng
Type
Article
Metadata
Show full item recordCitation
Thomson, L., Elleri, D., Bond, S., Howlett, J., Dunger, D. B., & Beardsall, K. (2019). Targeting glucose control in preterm infants: pilot studies of continuous glucose monitoring.. Archives of Disease in Childhood: Fetal and Neonatal Edition https://doi.org/10.1136/archdischild-2018-314814
Abstract
OBJECTIVE: Hyperglycaemia is common in very preterm infants and is associated with adverse outcomes. Preventing hyperglycaemia without increasing the risk of hypoglycaemia is difficult. Real time tracking with continuous glucose monitors (CGM) may improve glucose control. We assessed the feasibility and safety of CGM to target glucose control in preterm infants, to inform a randomised controlled trial (RCT). DESIGN: We performed a single centre study in very preterm infants during the first week of life. Accuracy was assessed by comparison of CGM with blood glucose levels (n=20 infants). In a separate pilot study of efficacy (n=20), real-time CGM combined with a paper guideline to target glucose control (2.6-10 mmol/L) was compared with standard neonatal care (masked CGM). Questionnaires were used to assess staff acceptability. RESULTS: No concerns were raised about infection or skin integrity at sensor site. The sensor performed well compared with point-of-care blood glucose measurements, mean bias of -0.27 (95% CI -0.35 to -0.19). Per cent time in target range (sensor glucose 2.6-10 mmol/L) was greater with CGM than POC (77% vs 59%, respectively) and per cent time sensor glucose >10 mmol/L was less with CGM than POC (24% vs 40%, respectively). The CGM also detected clinically unsuspected episodes of hypoglycaemia. Staff reported that the use of the CGM positively improved clinical care. CONCLUSIONS: This study suggests that CGM has sufficient accuracy and utility in preterm infants to warrant formal testing in a RCT.
Keywords
continuous glucose monitoring, glucose, hyperglycaemia, hypoglycaemia
Sponsorship
Funding was provided by the Efficacy and Mechanism Evaluation (EME) Programme, an MRC and NIHR partnership and the Evelyn Trust, Cambridge. Medtronic provided the CGM system and sensors, and support was received from the NIHR Cambridge Biomedical Research Centre. Medtronic had no role in design of the study, the gathering of data, access to data, preparation of the manuscript or decision to publish the results. The study was jointly sponsored by the University of Cambridge and Cambridge University Hospitals NHS Foundation Trust.
Funder references
Medical Research Council (MC_UU_12012/5)
NETSCC (None)
Identifiers
External DOI: https://doi.org/10.1136/archdischild-2018-314814
This record's URL: https://www.repository.cam.ac.uk/handle/1810/285928
Rights
Licence:
http://www.rioxx.net/licenses/all-rights-reserved
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk