Validation of a new fully automated software for 2D digital mammographic breast density evaluation in predicting breast cancer risk.
View / Open Files
Authors
Giorgi Rossi, Paolo
Hélin, Valerie
Astley, Susan
Mantellini, Paola
Nitrosi, Andrea
Harkness, Elaine F
Gauthier, Emilien
Puliti, Donella
Balleyguier, Corinne
Baron, Camille
Gilbert, Fiona J
Grivegnée, André
Pattacini, Pierpaolo
Michiels, Stefan
Delaloge, Suzette
Publication Date
2021-10-06Journal Title
Sci Rep
ISSN
2045-2322
Publisher
Springer Science and Business Media LLC
Volume
11
Issue
1
Pages
19884
Language
eng
Type
Article
This Version
VoR
Physical Medium
Electronic
Metadata
Show full item recordCitation
Giorgi Rossi, P., Djuric, O., Hélin, V., Astley, S., Mantellini, P., Nitrosi, A., Harkness, E. F., et al. (2021). Validation of a new fully automated software for 2D digital mammographic breast density evaluation in predicting breast cancer risk.. Sci Rep, 11 (1), 19884. https://doi.org/10.1038/s41598-021-99433-3
Abstract
We compared accuracy for breast cancer (BC) risk stratification of a new fully automated system (DenSeeMammo-DSM) for breast density (BD) assessment to a non-inferiority threshold based on radiologists' visual assessment. Pooled analysis was performed on 14,267 2D mammograms collected from women aged 48-55 years who underwent BC screening within three studies: RETomo, Florence study and PROCAS. BD was expressed through clinical Breast Imaging Reporting and Data System (BI-RADS) density classification. Women in BI-RADS D category had a 2.6 (95% CI 1.5-4.4) and a 3.6 (95% CI 1.4-9.3) times higher risk of incident and interval cancer, respectively, than women in the two lowest BD categories. The ability of DSM to predict risk of incident cancer was non-inferior to radiologists' visual assessment as both point estimate and lower bound of 95% CI (AUC 0.589; 95% CI 0.580-0.597) were above the predefined visual assessment threshold (AUC 0.571). AUC for interval (AUC 0.631; 95% CI 0.623-0.639) cancers was even higher. BD assessed with new fully automated method is positively associated with BC risk and is not inferior to radiologists' visual assessment. It is an even stronger marker of interval cancer, confirming an appreciable masking effect of BD that reduces mammography sensitivity.
Sponsorship
European Commission Horizon 2020 (H2020) Societal Challenges (755394)
Identifiers
External DOI: https://doi.org/10.1038/s41598-021-99433-3
This record's URL: https://www.repository.cam.ac.uk/handle/1810/329437