Viscous liquids in bubble columns
View / Open Files
Authors
Philip, Jojo
Advisors
Davidson, John
Date
1987Awarding Institution
University of Cambridge
Author Affiliation
Department of Chemical Engineering and Biotechnology
Qualification
Doctor of Philosophy (PhD)
Language
English
Type
Thesis
Metadata
Show full item recordCitation
Philip, J. (1987). Viscous liquids in bubble columns (Doctoral thesis). https://doi.org/10.17863/CAM.79285
Abstract
This dissertation is concerned with studies of highly viscous Newtonian and non-Newtonian liquids in bubble columns with, and without, draft tubes. The importance of the parameters influencing bubble column reactors is discussed with reference to previous work.
The shapes and rise velocities of single bubbles in these liquids were studied in an 8.8cm diameter column, and the gas holdup, resulting from continuous bubbling of gas into this column, was also measured. Agreement between holdup predicted by the equation of Nicklin et al (1962), and experimental data in the present work and that of other workers is good. The limiting result of Dumitrescu (1943) was found to apply for fully developed slug flow in viscous non-Newtonian liquids in large columns.
Gas holdup, in a 15cm diameter bubble column with a draft tube, consisted of large bubbles (slugs), which rapidly rose through the liquid, and very small bubbles, which accumulated in the liquid. These small bubbles were generated near the gas distributor and also at the liquid surface; less than 1% of the total gas flowrate into the system was converted into small bubbles for a highly viscous Newtonian liquid. The gas holdup due to small bubbles in non-Newtonian liquids was much less than that in Newtonian liquids. Large bubble velocities deduced from the bubble column measurements were consistent with the single bubble measurements.
Liquid velocities in the 15cm column were measured by a neutrally buoyant flow follower; the liquid circulation rate was found to decrease with an increase in liquid viscosity. A model to predict the liquid circulation rate is outlined.
The effect of scale-up on the gas holdup and liquid circulation rate was also studied experimentally in a 60cm square bubble column with a 30cm square draft tube. The bubble size distribution in this column was similar to the 15cm column but liquid velocities were higher, and gas holdup was smaller in the 60cm column.
Keywords
Bubble columns, Viscous liquids
Identifiers
This record's DOI: https://doi.org/10.17863/CAM.79285
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk