Research data supporting "Conformable and robust microfluidic force sensors to enable precision joint replacement surgery"
dc.contributor.author | Ives, Liam | |
dc.contributor.author | Pace, Alizée | |
dc.contributor.author | Bor, Fabian | |
dc.contributor.author | Jing, Qingshen | |
dc.contributor.author | Wade, Tom | |
dc.contributor.author | Cama, Jehangir | |
dc.contributor.author | Khanduja, Vikas | |
dc.contributor.author | Kar-Narayan, Sohini | |
dc.date.accessioned | 2022-05-27T09:39:17Z | |
dc.date.available | 2022-05-27T09:39:17Z | |
dc.identifier.uri | https://www.repository.cam.ac.uk/handle/1810/337538 | |
dc.description | Research data supporting "Conformable and robust microfluidic force sensors to enable precision joint replacement surgery", to plot all figures in the main manuscript and supporting information. The data was collected from experiments and simulations. The experimental data was collected using an impedance analyser and load cell. Please see included README files for further details | |
dc.description.sponsorship | LI acknowledges support from an EPSRC Doctoral Training Partnership studentship (EP/R513180/1). TW acknowledges support from an EPSRC Doctoral Training Partnership studentship (EP/T517847/1). SKN is grateful for support from ERC Starting Grant (Grant No. ERC-2014-STG-639526, NANOGEN). SKN and QJ acknowledge support from the Centre of Advanced Materials for Integrated Energy Systems ''CAM-IES'' grant EP/P007767/1. JC was currently supported by a Wellcome Trust Institutional Strategic Support Award to the University of Exeter (204909/Z/16/Z); for the purpose of Open Access, the author has applied a CC BY public copyright license to any Author Accepted Manuscript version arising from this submission. | |
dc.format | Microsoft Excel, Python | |
dc.rights | Attribution 4.0 International (CC BY 4.0) | |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | microfluidics | |
dc.subject | force sensor | |
dc.subject | total hip replacement | |
dc.subject | additive manufacturing | |
dc.subject | orthopaedic surgery | |
dc.title | Research data supporting "Conformable and robust microfluidic force sensors to enable precision joint replacement surgery" | |
dc.type | Dataset | |
dc.publisher.department | Department of Materials Science and Metallurgy | |
dc.date.updated | 2022-05-17T09:04:18Z | |
dc.identifier.doi | 10.17863/CAM.84650 | |
rioxxterms.licenseref.uri | https://creativecommons.org/licenses/by/4.0/ | |
datacite.contributor.supervisor | Kar-Narayan, Sohini | |
dcterms.format | .xls, .csv, .txt, .sig, .spec, .doc, .docx | |
dc.contributor.orcid | Ives, Liam [0000-0001-8705-7269] | |
dcterms.relation | https://doi.org/10.1016/j.matdes.2022.110747 | |
rioxxterms.type | Other | |
pubs.funder-project-id | Engineering and Physical Sciences Research Council (2277393) | |
datacite.issupplementto.doi | https://doi.org/10.1016/j.matdes.2022.110747 | |
datacite.issupplementto.doi | https://doi.org/10.17863/CAM.84414 | |
datacite.issupplementto.url | https://www.repository.cam.ac.uk/handle/1810/336994 | |
cam.depositDate | 2022-05-17 | |
pubs.licence-identifier | apollo-deposit-licence-2-1 | |
pubs.licence-display-name | Apollo Repository Deposit Licence Agreement |