Unencapsulated and washable two-dimensional material electronic-textile for NO2 sensing in ambient air.
View / Open Files
Authors
Oluwasanya, Pelumi W
Carey, Tian
Samad, Yarjan Abdul
Occhipinti, Luigi G
Publication Date
2022-07-19Journal Title
Sci Rep
ISSN
2045-2322
Publisher
Nature Publishing Group
Type
Article
This Version
AM
Metadata
Show full item recordCitation
Oluwasanya, P. W., Carey, T., Samad, Y. A., & Occhipinti, L. G. (2022). Unencapsulated and washable two-dimensional material electronic-textile for NO2 sensing in ambient air.. Sci Rep https://doi.org/10.1038/s41598-022-16617-1
Abstract
Materials adopted in electronic gas sensors, such as chemiresistive-based NO2 sensors, for integration in clothing fail to survive standard wash cycles due to the combined effect of aggressive chemicals in washing liquids and mechanical abrasion. Device failure can be mitigated by using encapsulation materials, which, however, reduces the sensor performance in terms of sensitivity, selectivity, and therefore utility. A highly sensitive NO2 electronic textile (e-textile) sensor was fabricated on Nylon fabric, which is resistant to standard washing cycles, by coating Graphene Oxide (GO), and GO/Molybdenum disulfide (GO/MoS2) and carrying out in situ reduction of the GO to Reduced Graphene Oxide (RGO). The GO/MoS2 e-textile was selective to NO2 and showed sensitivity to 20 ppb NO2 in dry air (0.05%/ppb) and 100 ppb NO2 in humid air (60% RH) with a limit of detection (LOD) of ~ 7.3 ppb. The selectivity and low LOD is achieved with the sensor operating at ambient temperatures (~ 20 °C). The sensor maintained its functionality after undergoing 100 cycles of standardised washing with no encapsulation. The relationship between temperature, humidity and sensor response was investigated. The e-textile sensor was embedded with a microcontroller system, enabling wireless transmission of the measurement data to a mobile phone. These results show the potential for integrating air quality sensors on washable clothing for high spatial resolution (< 25 cm2)-on-body personal exposure monitoring.
Relationships
Is supplemented by: https://doi.org/10.17863/CAM.85441
Sponsorship
European Commission Horizon 2020 (H2020) Research Infrastructures (RI) (685758)
Technology Strategy Board (103543)
European Commission Horizon 2020 (H2020) Future and Emerging Technologies (FET) (881603)
Identifiers
External DOI: https://doi.org/10.1038/s41598-022-16617-1
This record's URL: https://www.repository.cam.ac.uk/handle/1810/339120
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk