Repository logo
 

The effects of despeckling filters on pore size measurements in collagen scaffold micro‐CT data

Published version
Peer-reviewed

Change log

Abstract

Summary: Micro‐CT is often used to assess the characteristics of porous structures such as tissue engineering scaffolds and trabecular bone. Prior to analysis, micro‐CT images can be thresholded and filtered to remove noise. Scaffold pore size affects mechanical properties and biological cell behaviour and is a frequently assessed parameter. This paper identifies and characterizes an artefact affecting a commonly used filter which erroneously increases mean pore size. The 3D sweep despeckling filter removes all but the largest object within a volume of interest, and therefore deletes any disconnected objects located at the periphery, increasing measured mean pore size. This artefact is characterized, and effective methods to mitigate its effects are devised, involving despeckling a sufficiently large volume of interest, then reducing the volume of interest in size to remove the error prior to analysis. Techniques to effectively apply this method to other data sets are described. This method eliminates the artefact but is time‐consuming and computationally expensive. Alternative, more economical filters which remove objects below a specified size are also assessed but are shown to be affected by the same artefact. These results will help to guide the implementation of future studies investigating the effects of pore size.

Description

Funder: Department of Materials Science and Metallurgy, University of Cambridge; Id: http://dx.doi.org/10.13039/501100006299

Keywords

ORIGINAL ARTICLE, ORIGINAL ARTICLES, collagen, filters, micro‐CT, pore size, processing, scaffolds

Journal Title

Journal of Microscopy

Conference Name

Journal ISSN

0022-2720
1365-2818

Volume Title

Publisher

Sponsorship
Engineering and Physical Sciences Research Council (EP/N019938/1)
Relationships
Is supplemented by: