Repository logo
 

The impact of using Closed Cavity Façades (CCF) on buildings’ thermal and visual performance

dc.contributor.authorMichael, M
dc.contributor.authorOverend, M
dc.contributor.orcidOverend, Mauro [0000-0001-5929-497X]
dc.date.accessioned2021-12-15T16:27:46Z
dc.date.available2021-12-15T16:27:46Z
dc.date.issued2021-11-01
dc.date.updated2021-12-15T16:27:45Z
dc.description.abstract<jats:title>Abstract</jats:title> <jats:p>Glazing is a critical buildings element as it is the most vulnerable envelope part to heat gain and heat loss accounting for around 50% of a building’s energy consumption. However, conventional glazing technologies have relatively low-performance characteristics which cause significant heat losses during winter and undesired heat gain in summer. In this regard, this study investigates the thermal and visual performance of various design configurations of a novel glazing technology, named Closed Cavity Façade (CCF), in comparison with traditional glazing technologies. Several CCF configurations were examined using Energy Plus and IDA ICE and compared to the baseline Double Glazing Unit (DGU) (traditional or thermochromic). MATELab, an office-like test facility at the University of Cambridge was used as the model for the simulations, which was beforehand experimentally validated. The results showed extensive benefits of CCFs compared to DGU systems, in terms of thermal performance and comfort. A 22-41% or 21-37% decrease in annual total energy consumption, compared to traditional DGU or thermochromic respectively, are identified along with a positive effect on thermal comfort with a significant reduction in radiant discomfort. Further investigation showed that glass coatings and solar shading device’s characteristics play an important role in achieving further performance improvements.</jats:p>
dc.identifier.doi10.17863/CAM.78982
dc.identifier.eissn1742-6596
dc.identifier.issn1742-6588
dc.identifier.otherjpcs_2069_1_012021
dc.identifier.otherj20691021
dc.identifier.urihttps://www.repository.cam.ac.uk/handle/1810/331528
dc.languageen
dc.language.isoeng
dc.publisherIOP Publishing
dc.publisher.urlhttp://dx.doi.org/10.1088/1742-6596/2069/1/012021
dc.subject51 Physical Sciences
dc.subject7 Affordable and Clean Energy
dc.titleThe impact of using Closed Cavity Façades (CCF) on buildings’ thermal and visual performance
dc.typeArticle
prism.issueIdentifier1
prism.publicationNameJournal of Physics: Conference Series
prism.volume2069
rioxxterms.licenseref.urihttp://creativecommons.org/licenses/by/3.0/
rioxxterms.versionVoR
rioxxterms.versionofrecord10.1088/1742-6596/2069/1/012021

Files

Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
metadata.xml
Size:
5.7 KB
Format:
Extensible Markup Language
Description:
Bibliographic metadata
Licence
http://creativecommons.org/licenses/by/3.0/
Loading...
Thumbnail Image
Name:
pdf.pdf
Size:
573.4 KB
Format:
Adobe Portable Document Format
Description:
Published version
Licence
http://creativecommons.org/licenses/by/3.0/