Practicable assessment of cochlear size and shape from clinical CT images.
dc.contributor.author | Gee, Andrew H | |
dc.contributor.author | Zhao, Yufeng | |
dc.contributor.author | Treece, Graham M | |
dc.contributor.author | Bance, Manohar L | |
dc.contributor.orcid | Treece, Graham [0000-0003-0047-6845] | |
dc.date.accessioned | 2020-07-30T08:54:46Z | |
dc.date.available | 2020-07-30T08:54:46Z | |
dc.date.issued | 2021-02-10 | |
dc.description.abstract | There is considerable interpersonal variation in the size and shape of the human cochlea, with evident consequences for cochlear implantation. The ability to characterize a specific cochlea, from preoperative computed tomography (CT) images, would allow the clinician to personalize the choice of electrode, surgical approach and postoperative programming. In this study, we present a fast, practicable and freely available method for estimating cochlear size and shape from clinical CT. The approach taken is to fit a template surface to the CT data, using either a statistical shape model or a locally affine deformation (LAD). After fitting, we measure cochlear size, duct length and a novel measure of basal turn non-planarity, which we suggest might correlate with the risk of insertion trauma. Gold-standard measurements from a convenience sample of 18 micro-CT scans are compared with the same quantities estimated from low-resolution, noisy, pseudo-clinical data synthesized from the same micro-CT scans. The best results were obtained using the LAD method, with an expected error of 8-17% of the gold-standard sample range for non-planarity, cochlear size and duct length. | |
dc.format.medium | Electronic | |
dc.identifier.doi | 10.17863/CAM.55677 | |
dc.identifier.eissn | 2045-2322 | |
dc.identifier.issn | 2045-2322 | |
dc.identifier.other | ARTN 3448 | |
dc.identifier.uri | https://www.repository.cam.ac.uk/handle/1810/308590 | |
dc.language.iso | eng | |
dc.publisher | Springer Science and Business Media LLC | |
dc.rights | All Rights Reserved | |
dc.rights.uri | https://www.rioxx.net/licenses/all-rights-reserved/ | |
dc.subject | Cochlea | |
dc.subject | Cochlear Implantation | |
dc.subject | Cochlear Implants | |
dc.subject | Humans | |
dc.subject | Organ Size | |
dc.subject | Temporal Bone | |
dc.subject | Tomography, X-Ray Computed | |
dc.title | Practicable assessment of cochlear size and shape from clinical CT images. | |
dc.type | Report | |
dcterms.format | Electronic | |
prism.publicationDate | 2021 | |
prism.startingPage | 3448 | |
rioxxterms.licenseref.startdate | 2021-02-10 | |
rioxxterms.licenseref.uri | https://www.rioxx.net/licenses/all-rights-reserved/ | |
rioxxterms.type | Technical Report | |
rioxxterms.versionofrecord | 10.1038/s41598-021-83059-6 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- gee_tr004.pdf
- Size:
- 2.35 MB
- Format:
- Adobe Portable Document Format
- Licence
- https://www.rioxx.net/licenses/all-rights-reserved/
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- DepositLicenceAgreementv2.1.pdf
- Size:
- 150.9 KB
- Format:
- Adobe Portable Document Format