Research data supporting: "Molecular Dipole Buffer Layer Enabling Compact Interfaces in Perovskite Solar Cells"
Repository URI
Repository DOI
Change log
Description
Detailed description: This dataset contains raw and processed data supporting the manuscript, including:
- EQE data: External Quantum Efficiency spectra were recorded using a Keithley 2400 source meter under monochromatic light irradiation from a xenon lamp.
- JV curves: J–V curves were obtained under simulated AM 1.5G solar illumination with an intensity of 100 mW/cm², used for efficiency calculation under an N₂ atmosphere using a Keithley 2400 source meter. (To evaluate the impact of BTI-N on device performance, inverted PSCs with a structure of ITO/MeO-2PACz (HTL)/perovskite/PCBM (ETL)/Ag were fabricated, comparing PCBM-only, BCP/PCBM, and BTI-N/PCBM configurations.)
- ToF-SIMS data: Depth profiling results showing elemental distribution across the device layers. (ToF-SIMS depth profiling was performed on devices with BCP/Ag and BTI-N/Ag structures before and after heating at 120 °C for 24 h in ambient conditions (Figure 3e, f), using a thin Ag layer (~20 nm))
- UPS data: Ultraviolet Photoelectron Spectroscopy measurements for determining the work function and valence band maximum of the electrode and buffer-modified surfaces. (UPS spectra of bare Ag electrodes compared with those coated by the BTI-N layer.)
- XPS data: X-ray Photoelectron Spectroscopy measurements for analyzing elemental composition and chemical states at the electrode/buffer interface. (The XPS spectra of the Ag 3d regions for pristine and Ag-deposited BTI-N films )
- AFM : Atomic force microscopy (AFM) analysis was performed using a high-resolution MFP-3D AFM system (Asylum Research/Oxford Instruments) operated in tapping mode, employing aluminum-coated silicon probes (Tap-150Al-G, BudgetSensors). For each buffer layer condition, five independent samples were measured, with three to five areas scanned per sample to ensure statistical consistency and representative evaluation of surface morphology.)
- PL mapping : Wide-field microscopy was conducted using a Photon etc. IMA system, equipped with a 20× magnification Olympus objective lens (NA = 0.8). To correct for optical aberrations, the system was calibrated with a reference sample, allowing us to determine the post-processing parameters needed to correct image distortions. Chromatic aberrations were minimized by calibrating the z-position of the sample for each collected wavelength. A continuous wave 405 nm laser with intensity of 170 mW/cm² served as the excitation source, filtered through a high-quality 405 nm Semrock dichroic mirror to separate the photoluminescence signal from the excitation. The emitted light from the sample was directed onto a Hamamatsu CMOS camera with a 2048×2048 pixel array. During the measurement, the encapsulated device was switched to open-circuit or short-circuit by connection to a Keithley 2450. The PL mapping dataset consists of six files, which correspond directly to the distributions shown in Figure 4a–f of the manuscript: (a) PCBM-only under OC, (b) BSP/PCBM under OC, (c) BTI-N/PCBM under OC, (d) PCBM-only under SC, (e) BCP/PCBM under SC, and (f) BTI-N/PCBM under SC. Additionally, histogram plots of PL intensity under OC and SC conditions are shown in Figure 4g–h. These plots were generated from the datasets described above.
Version
Software / Usage instructions
Origin pro and HDF viewer can be used to open the dataset files.
Keywords
Publisher
Rights and licensing
Except where otherwised noted, this item's license is described as https://creativecommons.org/licenses/by-nc/4.0/