Show simple item record

dc.contributor.authorSovio, Ullaen
dc.contributor.authorMoraitis, Alexandrosen
dc.contributor.authorWong, Hilaryen
dc.contributor.authorSmith, Gordonen
dc.date.accessioned2017-07-14T13:12:24Z
dc.date.available2017-07-14T13:12:24Z
dc.identifier.issn0960-7692
dc.identifier.urihttps://www.repository.cam.ac.uk/handle/1810/265373
dc.description.abstractObjective To compare the diagnostic effectiveness of selective versus universal ultrasonography as a screening test for large for gestational age (LGA) infants, and to determine whether previously described ultrasonic markers of excessive fetal growth could identify which suspected LGA fetuses were at increased risk of neonatal morbidity. Methods We analysed data from a prospective cohort study of nulliparous women, the Pregnancy Outcome Prediction study. All women had clinically indicated scans as per routine care. Additionally, all women had blinded ultrasonic estimated fetal weight (EFW) performed at around 36 weeks of gestational age (wkGA). Screen positive for LGA was defined as an EFW >90th percentile ≥34wkGA. Results The current analysis included 3,866 eligible women. Of these, 177 (5%) infants had a birth weight >90th percentile. 1,354 (35%) women had a clinically indicated ultrasonography ≥34wkGA. The sensitivity of selective ultrasonography was 27% and the sensitivity of universal ultrasonography was 38%. The specificity of both approaches was high (99% and 97%, respectively). Using universal ultrasonography, neonatal outcome differed (P for interaction) by abdominal circumference growth velocity (ACGV) for both any neonatal morbidity (P = 0.08) and severe adverse neonatal outcome (P = 0.03). LGA fetuses with increased ACGV had a relative risk (95% CI, P) of any neonatal morbidity of 2.0 (1.1-3.6, P = 0.04) and severe adverse neonatal outcome of 6.5 (2.0-21.1, P = 0.01), whereas LGA fetuses with normal ACGV were not at increased risk. Conclusion Screening using universal ultrasonographic fetal biometry increases the detection of LGA infants and combined with ACGV identifies infants at increased risk of adverse neonatal outcome.
dc.description.sponsorshipThe work was supported by the National Institute for Health Research (NIHR) Cambridge Comprehensive Biomedical Research Centre (Women's Health theme), and a project grant from the Stillbirth and neonatal death society (Sands). The study was also supported GE Healthcare (donation of two Voluson i ultrasound systems for this study), and by the NIHR Cambridge Clinical Research Facility, where all research visits took place.
dc.languageengen
dc.language.isoenen
dc.publisherWiley
dc.subjectlarge for gestational ageen
dc.subjectmacrosomiaen
dc.subjectscreeningen
dc.subjectultrasounden
dc.subjectneonatal morbidityen
dc.titleUniversal versus selective ultrasonography to screen for large for gestational age infants and associated morbidityen
dc.typeArticle
prism.publicationNameUltrasound in Obstetrics and Gynecologyen
dc.identifier.doi10.17863/CAM.11535
dcterms.dateAccepted2017-04-14en
rioxxterms.versionofrecord10.1002/uog.17491en
rioxxterms.versionAMen
rioxxterms.licenseref.urihttp://www.rioxx.net/licenses/all-rights-reserveden
rioxxterms.licenseref.startdate2017-04-14en
dc.contributor.orcidSovio, Ulla [0000-0002-0799-1105]
dc.contributor.orcidMoraitis, Alexandros [0000-0003-4634-1129]
dc.contributor.orcidWong, Hilary [0000-0003-4597-1794]
dc.contributor.orcidSmith, Gordon [0000-0003-2124-0997]
dc.identifier.eissn1469-0705
rioxxterms.typeJournal Article/Reviewen
cam.issuedOnline2017-04-20en
rioxxterms.freetoread.startdate2018-04-20


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record