Repeatability of diffusion-weighted MRI of the prostate using whole lesion ADC values, skew and histogram analysis.
View / Open Files
Authors
Lawrence, Edward M
Priest, Andrew N
Warren, Anne Y
Gnanapragasam, Vincent J
Gallagher, Ferdia A
Publication Date
2019-01Journal Title
Eur J Radiol
ISSN
0720-048X
Publisher
Elsevier BV
Volume
110
Pages
22-29
Language
eng
Type
Article
This Version
VoR
Physical Medium
Print-Electronic
Metadata
Show full item recordCitation
Barrett, T., Lawrence, E. M., Priest, A. N., Warren, A. Y., Gnanapragasam, V. J., Gallagher, F. A., & Sala, E. (2019). Repeatability of diffusion-weighted MRI of the prostate using whole lesion ADC values, skew and histogram analysis.. Eur J Radiol, 110 22-29. https://doi.org/10.1016/j.ejrad.2018.11.014
Abstract
PURPOSE: To investigate the repeatability of diffusion-weighted imaging parameter including ADC-derived histogram values in prostate cancer. METHODS: 10 patients with prostate cancer were prospectively recruited to a retest cohort. 3 T diffusion-weighted MRI of the prostate was acquired consecutively with patient getting off the scanner between studies. Prostatectomy-histopathology defined tumour regions-of-interest were outlined on ADC maps and diffusion-weighted metrics including histograms were calculated. The coefficient of reproducibility (CoR) and Bland-Altman plots were used to assess repeatability. RESULTS: 10th centile, 90th centile, and median ADC showed good repeatability with mean difference ranging from -0.005 to -0.025 × 103 mm2s-1, and CoR ranging from 0.271-0.294 × 103 mm2s-1 of scan 1 mean). Two measures of heterogeneity and simplified texture, IQR and mean local range, had only moderate repeatability. IQR had a mean difference of -0.032 × 103 mm2s-1 between scans with CoR 0.181 × 103 mm2s-1 (56% of scan 1 mean). Mean local range had a mean difference -0.008 × 103 mm2s-1 between scans (37% of scan 1 mean). Bland-Altman plots showed good repeatability for test and re-test analysis for median, percentile and mean range values. All ADC values had good reliability regardless of whether the tumour border was included in quantitative analysis. ADC histogram skew had poor repeatability, CoR 0.78 × 103 mm2s-1 (373% of scan 1 mean). CONCLUSION: 10th and 90th centile ADC demonstrated sufficient repeatability for clinical use. However, more advanced measures of heterogeneity such as histogram skew, IQR, or mean local range may be limited by their repeatability.
Keywords
Magnetic resonance imaging, Prostate cancer diffusion, Reproducibility of results, Adult, Aged, Cohort Studies, Diffusion Magnetic Resonance Imaging, Humans, Image Interpretation, Computer-Assisted, Male, Middle Aged, Prospective Studies, Prostatectomy, Prostatic Neoplasms, Reproducibility of Results, Tumor Burden
Sponsorship
Cancer Research Uk (None)
Identifiers
External DOI: https://doi.org/10.1016/j.ejrad.2018.11.014
This record's URL: https://www.repository.cam.ac.uk/handle/1810/286994
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk