Evaluation of Acute Supplementation With the Ketone Ester (R)-3-Hydroxybutyl-(R)-3-Hydroxybutyrate (deltaG) in Healthy Volunteers by Cardiac and Skeletal Muscle 31P Magnetic Resonance Spectroscopy.
View / Open Files
Authors
Cameron, Donnie
Soto-Mota, Adrian
Willis, David R
Ellis, Jane
Procter, Nathan EK
Greenwood, Richard
Saunders, Neil
Schulte, Rolf F
Vassiliou, Vassilios S
Tyler, Damian J
Schmid, Albrecht Ingo
Rodgers, Christopher T
Malcolm, Paul N
Clarke, Kieran
Frenneaux, Michael P
Valkovič, Ladislav
Publication Date
2022Journal Title
Front Physiol
ISSN
1664-042X
Publisher
Frontiers Media
Type
Article
This Version
AM
Metadata
Show full item recordCitation
Cameron, D., Soto-Mota, A., Willis, D. R., Ellis, J., Procter, N. E., Greenwood, R., Saunders, N., et al. (2022). Evaluation of Acute Supplementation With the Ketone Ester (R)-3-Hydroxybutyl-(R)-3-Hydroxybutyrate (deltaG) in Healthy Volunteers by Cardiac and Skeletal Muscle 31P Magnetic Resonance Spectroscopy.. Front Physiol https://doi.org/10.3389/fphys.2022.793987
Abstract
In this acute intervention study, we investigated the potential benefit of ketone supplementation in humans by studying cardiac phosphocreatine to adenosine-triphosphate ratios (PCr/ATP) and skeletal muscle PCr recovery using phosphorus magnetic resonance spectroscopy (31P-MRS) before and after ingestion of a ketone ester drink. We recruited 28 healthy individuals: 12 aged 23-70 years for cardiac 31P-MRS, and 16 aged 60-75 years for skeletal muscle 31P-MRS. Baseline and post-intervention resting cardiac and dynamic skeletal muscle 31P-MRS scans were performed in one visit, where 25 g of the ketone monoester, deltaG®, was administered after the baseline scan. Administration was timed so that post-intervention 31P-MRS would take place 30 min after deltaG® ingestion. The deltaG® ketone drink was well-tolerated by all participants. In participants who provided blood samples, post-intervention blood glucose, lactate and non-esterified fatty acid concentrations decreased significantly (-28.8%, p ≪ 0.001; -28.2%, p = 0.02; and -49.1%, p ≪ 0.001, respectively), while levels of the ketone body D-beta-hydroxybutyrate significantly increased from mean (standard deviation) 0.7 (0.3) to 4.0 (1.1) mmol/L after 30 min (p ≪ 0.001). There were no significant changes in cardiac PCr/ATP or skeletal muscle metabolic parameters between baseline and post-intervention. Acute ketone supplementation caused mild ketosis in blood, with drops in glucose, lactate, and free fatty acids; however, such changes were not associated with changes in 31P-MRS measures in the heart or in skeletal muscle. Future work may focus on the effect of longer-term ketone supplementation on tissue energetics in groups with compromised mitochondrial function.
Keywords
31P-MRS, 3T, 7T, heart, ketone bodies, ketone monoester, phosphorus MRS, skeletal muscle
Sponsorship
This study was funded by a combination of seed funding awarded to D.C. by Norwich Medical School, University of East Anglia, and funding from TdeltaS., Ltd. L.V is a Sir Henry Dale Fellow supported jointly by the Wellcome Trust and the Royal Academy (#221805/Z/20/Z), and he also acknowledges the support of the Slovak Grant Agencies VEGA (#2/0003/20) and APVV (#19-0032). A.I.S. was supported by The Austrian Science Fund (FWF) Schrödinger Fellowship (J 4043). C.T.R. is funded by a Sir Henry Dale Fellowship from the Wellcome Trust and the Royal Society (#098436/Z/12/B) and acknowledges support from the NIHR Cambridge Biomedical Research Centre (BRC-1215-20014). The views expressed are those of the author(s) and not necessarily those of the NIHR or the Department of Health and Social Care. J.E. was funded by the Medical Research Council.
Funder references
Wellcome Trust (Unknown)
Wellcome Trust (098436/Z/12/B)
Wellcome Trust (098436/Z/12/Z)
National Institute for Health Research (IS-BRC-1215-20014)
Identifiers
External DOI: https://doi.org/10.3389/fphys.2022.793987
This record's URL: https://www.repository.cam.ac.uk/handle/1810/332458
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk