Evaluation of Dynamic Contrast-Enhanced MRI Measures of Lung Congestion and Endothelial Permeability in Heart Failure: A Prospective Method Validation Study.
View / Open Files
Authors
Roberts, Alexandra
Roberts, Caleb
Patterson, Ilse
Slough, Rhys A
Schroyer, Rosemary
Fernando, Disala
Kumar, Subramanya
Lee, Sarah
Parker, Geoffrey JM
Sarov-Blat, Lea
McEniery, Carmel
Middlemiss, Jessica
Janiczek, Robert L
Publication Date
2022-03-27Journal Title
J Magn Reson Imaging
ISSN
1053-1807
Publisher
Wiley
Type
Article
This Version
AM
Physical Medium
Print-Electronic
Metadata
Show full item recordCitation
Cheriyan, J., Roberts, A., Roberts, C., Graves, M., Patterson, I., Slough, R. A., Schroyer, R., et al. (2022). Evaluation of Dynamic Contrast-Enhanced MRI Measures of Lung Congestion and Endothelial Permeability in Heart Failure: A Prospective Method Validation Study.. J Magn Reson Imaging https://doi.org/10.1002/jmri.28174
Abstract
BACKGROUND: Methods for accurate quantification of lung fluid in heart failure (HF) are needed. Dynamic contrast-enhanced (DCE)-MRI may be an appropriate modality. PURPOSE: DCE-MRI evaluation of fraction of fluid volume in the interstitial lung space (ve ) and vascular permeability (Ktrans ). STUDY TYPE: Prospective, single-center method validation. POPULATION: Seventeen evaluable healthy volunteers (HVs), 12 participants with HF, and 3 with acute decompensated HF (ADHF). FIELD STRENGTH/SEQUENCE: T1 mapping (spoiled gradient echo variable flip angle acquisition) followed by dynamic series (three-dimensional spoiled gradient-recalled echo acquisitions [constant echo time, repetition time, and flip angle at 1.5 T]). ASSESSMENT: Three whole-chest scans were acquired: baseline (Session 1), 1-week later (Session 2), following exercise (Session 3). Extended Tofts model quantified ve and Ktrans (voxel-wise basis); total lung median measures were extracted and fitted via repeat measure analysis of variance (ANOVA) model. Patient tolerability of the scanning protocol was assessed. STATISTICAL TESTS: This was constructed as an experimental medicine study. PRIMARY ENDPOINTS: Ktrans and ve at baseline (HV vs. HF), change in Ktrans and ve following exercise, and following lung congestion resolution (ADHF). Ktrans and ve were fitted separately using ANOVA. Secondary endpoint: repeatability, that is, within-participant variability in ve and Ktrans between sessions (coefficient of variation estimated via mixed effects model). RESULTS: There was no significant difference in mean Ktrans between HF and HV (P ≤ 0.17): 0.2216 minutes-1 and 0.2353 minutes-1 (Session 1), 0.2044 minutes-1 and 0.2567 minutes-1 (Session 2), 0.1841 minutes-1 and 0.2108 minutes-1 (Session 3), respectively. ve was greater in the HF group (all scans, P ≤ 0.02). Results were repeatable between Sessions 1 and 2; mean values for HF and HV were 0.4946 and 0.3346 (Session 1), 0.4353 and 0.3205 (Session 2), respectively. There was minimal difference in Ktrans or ve between scans for participants with ADHF (small population precluded significance testing). Scanning was well tolerated. DATA CONCLUSION: While no differences were detected in Ktrans , ve was greater in chronic HF patients vs. HV, augmented beyond plasma and intracellular volume. DCE-MRI is a valuable diagnostic and physiologic tool to evaluate changes in fluid volume in the interstitial lung space associated with symptomatic HF. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.
Keywords
DCE-MRI, edema, heart failure, lung congestion, pulmonary interstitium
Embargo Lift Date
2023-03-27
Identifiers
External DOI: https://doi.org/10.1002/jmri.28174
This record's URL: https://www.repository.cam.ac.uk/handle/1810/335695
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk