Repository logo
 

Effects of solution exposure on the combined axial-shear behaviour of unidirectional CFRP rods


Type

Article

Change log

Authors

Scott, P 
Lees, JM 

Abstract

In fibre reinforced polymer (FRP) prestressed concrete applications, an FRP tendon must sustain high axial tensile stresses and, if cracks occur, additional dowel forces. The tendon may also be exposed to solutions and so the combined axial-shear stress performance after long-term environmental exposure is important. Experiments were conducted to investigate the combined axial-shear stress failure envelope for unidirectional carbon FRP tendons which had been exposed to either water, salt water or concrete pore solution at 60 °C for approximately 18 months. The underlying load resisting mechanisms were found to depend on the loading configuration, restraint effects and the initial stress state. When saturated, CFRP tendons are likely to exhibit a reduced shear stiffness. However, the ultimate limit state appeared to be fibre-dominated and was therefore less susceptible to reductions due to solution uptake effects.

Description

Keywords

Carbon fibre, Thermosetting resin, Environmental degradation, Mechanical testing

Journal Title

Composites Part A: Applied Science and Manufacturing

Conference Name

Journal ISSN

1359-835X

Volume Title

43

Publisher

Elsevier BV
Sponsorship
The first author was funded by an EPSRC DTA award.