The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) offers unique possibilities. In this paper we aim to exploit the high spatial resolution of MRI to enhance the reconstruction of simultaneously acquired PET data. We propose a new prior to incorporate structural side information into a maximum a posteriori reconstruction. The new prior combines the strengths of previously proposed priors for the same problem: it is very efficient in guiding the reconstruction at edges available from the side information and it reduces locally to edge-preserving total variation in the degenerate case when no structural information is available. In addition, this prior is segmentation-free, convex and no a priori assumptions are made on the correlation of edge directions of the PET and MRI images. We present results for a simulated brain phantom and for real data acquired by the Siemens Biograph mMR for a hardware phantom and a clinical scan. The results from simulations show that the new prior has a better trade-off between enhancing common anatomical boundaries and preserving unique features than several other priors. Moreover, it has a better mean absolute bias-to-mean standard deviation trade-off and yields reconstructions with superior relative l2-error and structural similarity index. These findings are underpinned by the real data results from a hardware phantom and a clinical patient confirming that the new prior is capable of promoting well-defined anatomical boundaries.

Description

Keywords

Algorithms, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Phantoms, Imaging, Positron-Emission Tomography

Journal Title

IEEE Trans Med Imaging

Conference Name

Journal ISSN

0278-0062
1558-254X

Volume Title

Publisher

Institute of Electrical and Electronics Engineers (IEEE)
Sponsorship
Engineering and Physical Sciences Research Council (EP/M00483X/1)
Engineering and Physical Sciences Research Council (EP/N014588/1)
This research was funded by the EPSRC (EP/K005278/1) and EP/H046410/1 and supported by the National Institute for Health Research University College London Hospitals Biomedical Research Centre. M.J.E was supported by an IMPACT studentship funded jointly by Siemens and the UCL Faculty of Engineering Sciences. K.T. and D.A. are partially supported by the EPSRC grant EP/M022587/1.