Biases incurred from non-random repeat testing of haemoglobin levels in blood donors
View / Open Files
Authors
Chung, Ryan K
Wood, AM
Sweeting, Michael J
Publication Date
2019Journal Title
Biometrical Journal
ISSN
1521-4036
Publisher
Wiley-Blackwell
Type
Article
This Version
AM
Metadata
Show full item recordCitation
Chung, R. K., Wood, A., & Sweeting, M. J. (2019). Biases incurred from non-random repeat testing of haemoglobin levels in blood donors. Biometrical Journal https://doi.org/10.1002/bimj.201700268
Abstract
To help prevent anaemia, it is a requisite for blood donors to undergo a haemoglobin test to ensure levels are not too low before donation. It is therefore important to have an accurate testing device and strategy to ensure donors are not being inappropriately bled. A recent study in blood donors used a selective testing strategy where if a donor’s haemoglobin level is below the level required for donation, then another reading is taken and if this occurs again, a third and final reading is used. This strategy can reduce the average number of readings required per donor compared to taking three measurements for all donors. However, the final decision-making measurement will on average be higher than a single measurement. In this paper, a selective testing strategy is compared against other strategies. Individual-level biases are derived for the selective strategy and are shown to depend on how close a donor’s true haemoglobin level is to the donation threshold and the magnitude of error in the testing device. A simulation study was conducted using the distribution of haemoglobin levels from a large donor population to investigate the effects different strategies have on population performance. We consider scenarios based on varying the measurement device bias and error, including differential biases that depend on the underlying haemoglobin level. Discriminatory performance is shown to be affected when using the selective testing strategies, especially when measurement error is large and when differential bias is present in the device. We recommend that the average of a number of readings should be used in preference to selective testing strategies if multiple measurements are available.
Keywords
blood donation, diagnostic performance, multiple measurements, selective testing, simulation study
Sponsorship
Department of Health (via National Institute for Health Research (NIHR)) (NIHR BTRU-2014-10024)
Medical Research Council (MR/L003120/1)
British Heart Foundation (None)
Medical Research Council (G0701619)
Identifiers
External DOI: https://doi.org/10.1002/bimj.201700268
This record's URL: https://www.repository.cam.ac.uk/handle/1810/287145
Rights
Licence:
http://www.rioxx.net/licenses/all-rights-reserved
Statistics
Total file downloads (since January 2020). For more information on metrics see the
IRUS guide.
Recommended or similar items
The current recommendation prototype on the Apollo Repository will be turned off on 03 February 2023. Although the pilot has been fruitful for both parties, the service provider IKVA is focusing on horizon scanning products and so the recommender service can no longer be supported. We recognise the importance of recommender services in supporting research discovery and are evaluating offerings from other service providers. If you would like to offer feedback on this decision please contact us on: support@repository.cam.ac.uk