Repository logo
 

Novel approach for evaluating detector-related uncertainties in a LArTPC using MicroBooNE data

Published version
Peer-reviewed

Change log

Abstract

Primary challenges for current and future precision neutrino experiments using liquid argon time projection chambers (LArTPCs) include understanding detector effects and quantifying the associated systematic uncertainties. This paper presents a novel technique for assessing and propagating LArTPC detector-related systematic uncertainties. The technique makes modifications to simulation waveforms based on a parameterization of observed differences in ionization signals from the TPC between data and simulation, while remaining insensitive to the details of the detector model. The modifications are then used to quantify the systematic differences in low- and high-level reconstructed quantities. This approach could be applied to future LArTPC detectors, such as those used in SBN and DUNE.

Description

Journal Title

European Physical Journal C

Conference Name

Journal ISSN

1434-6044
1434-6052

Volume Title

Publisher

Springer Nature

Rights and licensing

Except where otherwised noted, this item's license is described as http://creativecommons.org/licenses/by/4.0/
Sponsorship
STFC (ST/S000712/1)